Peripherally Inserted Central Catheter (PICC)

Medical ISO Peripherally Inserted Central Catheter (PICC) for Long-Term Intravenous Access

Disposable Medical Device Peripherally Inserted Central Catheter (PICC)

I have found results from400+products and200+suppliers aboutPicc catheter








































B2B buyers should prioritize Medical-Grade Polyurethane or Silicone materials, as these offer the best balance between biocompatibility and kink resistance. Ensure the catheter features Radiopaque markers along its entire length for clear visibility under X-ray or fluoroscopy. For clinical efficiency, look for Power-Injectable models capable of withstanding high-pressure contrast injections (typically up to 300 psi). Additionally, verify that the kit includes a Nitinol hydrophilic guidewire to reduce friction during insertion.
As Class III medical devices, PICC catheters must adhere to stringent regulations. Suppliers must possess ISO 13485 certification for medical device quality management. For the US market, FDA 510(k) clearance is required; for the EU, CE Marking (MDR 2017/745) is essential. Furthermore, ensure the product meets ISO 10555 standards for sterile, single-use intravascular catheters to guarantee patient safety and performance consistency.
Focus on Valved vs. Non-valved designs; integrated valves (like Groshong valves) are preferred to reduce the risk of air embolism and blood reflux. Check for Antimicrobial or Heparin-coated options if your target market prioritizes the reduction of Catheter-Related Bloodstream Infections (CRBSI). Always request Biocompatibility Test Reports (ISO 10993) to ensure the materials do not cause systemic toxicity or sensitization.
Utilize Secure Payment Services provided by reputable platforms like Made-in-China.com, which offer escrow-style protection to ensure funds are only released upon proof of shipment. Always conduct a Third-Party Factory Audit to verify the supplier's 'Clean Room' (Class 100,000/ISO 8) environment, as sterile manufacturing is non-negotiable for PICC catheters.
PICC catheters are sensitive to environmental factors. Ensure the shipping contract specifies Temperature-controlled environments (avoiding extreme heat which degrades polymers) and Pressure-sensitive handling. The packaging must maintain Sterile Barrier Integrity; any puncture to the Tyvek pouches renders the batch unsellable. Confirm the Shelf Life (Expiry Date) is at least 2-3 years from the date of shipment to allow for local distribution.
Focus on Long-term Quality Consistency rather than just the lowest unit price. Negotiate for Sterilization Batch Certificates (COA/COC) to be included with every shipment. For bulk orders, request tiered pricing based on annual volume commitments, and seek a Defective Goods Replacement Clause that covers not just the product cost, but also the proportional shipping and customs duties incurred.