SourcingAI

Gc capillary column manufacturers

I have found results from400+products and200+suppliers aboutGc capillary column

Jiangxi Aiyi High Tech Co., Ltd.mic-icon
Satisfies 2/2 of your requirements
Ay-Gc-5 Medium Polarity Gc Capillary Column for Aromatic Hydrocarbons and General Analysis

Ay-Gc-5 Medium Polarity Gc Capillary Column for Aromatic Hydrocarbons and General Analysis

US$200.00-730.00
1 Piece(MOQ)
Sample Available
Peg-20m Equivalent High Polar Gas Chromatography Capillary Column for Alcohols Fatty Acids Fames Separation

Peg-20m Equivalent High Polar Gas Chromatography Capillary Column for Alcohols Fatty Acids Fames Separation

US$200.00-730.00
1 Piece(MOQ)
Sample Available
High Polarity Ffap Gc Capillary Column for Fatty Acid & Volatile Acid Analysis

High Polarity Ffap Gc Capillary Column for Fatty Acid & Volatile Acid Analysis

US$228.00-258.00
1 Piece(MOQ)
Sample Available
30m 0.25mm 0.33um Gas Chromatograph Capillary Gc Column for Oxide Detection

30m 0.25mm 0.33um Gas Chromatograph Capillary Gc Column for Oxide Detection

US$400.00
1 Piece(MOQ)
Sample Available
Gc-5 Gc Capillary Column 5% Phenyl Methylpolysiloxane Gas Chromatography Column for Agilent Db-5 HP-5 Equivalent

Gc-5 Gc Capillary Column 5% Phenyl Methylpolysiloxane Gas Chromatography Column for Agilent Db-5 HP-5 Equivalent

US$360.00
1 Set(MOQ)
Sample Available
100m X 0.25mm X 0.2μm Highly Polar Gc Capillary Column for Fame Cis/Trans Isomers Analysis (HP-88 Equivalent)

100m X 0.25mm X 0.2μm Highly Polar Gc Capillary Column for Fame Cis/Trans Isomers Analysis (HP-88 Equivalent)

US$1,745.00
1 Piece(MOQ)
Sample Available
Highly Polar Capillary Column Gc Column for Fame Fatty Acid Analysis

Highly Polar Capillary Column Gc Column for Fame Fatty Acid Analysis

US$560.00
1 Set(MOQ)
Sample Available
Ay-Gc-624 USP G43 0.33um Gc-Ms Column for Semiconductor Voc and Residual Solvent Testing

Ay-Gc-624 USP G43 0.33um Gc-Ms Column for Semiconductor Voc and Residual Solvent Testing

US$175.00-200.00
1 Piece(MOQ)
Sample Available
Ay-Gcx-Fame Highly Polar Cyanopropylphenyl Gc Column for Trans Fat, Food Fatty Acid Testing

Ay-Gcx-Fame Highly Polar Cyanopropylphenyl Gc Column for Trans Fat, Food Fatty Acid Testing

US$410.00-470.00
1 Piece(MOQ)
Sample Available
Ay-HP-5ms Chromatography Column Gc 30*0.25*0.25 Agilent Gc Compatible Column

Ay-HP-5ms Chromatography Column Gc 30*0.25*0.25 Agilent Gc Compatible Column

US$770.00
1 Piece(MOQ)
Sample Available
Ay-Gc-Plot-Q 0.53 mm X 40μm Gc Column for Semiconductor Gas and Hydrocarbon Analysis

Ay-Gc-Plot-Q 0.53 mm X 40μm Gc Column for Semiconductor Gas and Hydrocarbon Analysis

US$370.00-425.00
1 Piece(MOQ)
Sample Available
Ay-Gc-Plot-5A Molecular Sieve Column Gc for High-Purity Semiconductor Gas Detection

Ay-Gc-Plot-5A Molecular Sieve Column Gc for High-Purity Semiconductor Gas Detection

US$480.00-558.00
1 Piece(MOQ)
Sample Available
Ay-Gc-1 Non-Polar Gc Capillary Column for Volatile Organic Compounds (VOC) Analysis

Ay-Gc-1 Non-Polar Gc Capillary Column for Volatile Organic Compounds (VOC) Analysis

US$150.00-950.00
1 Piece(MOQ)
Sample Available
Aiyi Gas Chromatography Column Ay-Gc-5 Gc Capillary Column for All Brands

Aiyi Gas Chromatography Column Ay-Gc-5 Gc Capillary Column for All Brands

US$110.00
1 Set(MOQ)
Sample Available
5 Phenyl 95 Dimethylpolysiloxane Gc-5 Fused Silica Capillary Column

5 Phenyl 95 Dimethylpolysiloxane Gc-5 Fused Silica Capillary Column

US$98.00-110.00
1 Set(MOQ)
Sample Available
Low Bleed Gc-1 Gas Chromatography Column 100% Pdms Capillary Gc Column for Vocs and Solvents Testing

Low Bleed Gc-1 Gas Chromatography Column 100% Pdms Capillary Gc Column for Vocs and Solvents Testing

US$160.00-170.00
1 Piece(MOQ)
Sample Available
Ay-Gc-17 MID-Polarity Gc Column for Pesticides Analysis

Ay-Gc-17 MID-Polarity Gc Column for Pesticides Analysis

US$320.00-760.00
1 Piece(MOQ)
Sample Available
100% Dimethyl Polysiloxane Non-Polar Capillary Column for Solvents & General Organic Analysis

100% Dimethyl Polysiloxane Non-Polar Capillary Column for Solvents & General Organic Analysis

US$136.00-145.00
1 Piece(MOQ)
Sample Available
Ay-Gcx-5ms Fused Silica Gas Chromatography Capillary Column

Ay-Gcx-5ms Fused Silica Gas Chromatography Capillary Column

US$660.00
1 Set(MOQ)
Sample Available
Ay-Gdx-101 3mm Glass Packed Gc Column for Gas Analysis

Ay-Gdx-101 3mm Glass Packed Gc Column for Gas Analysis

US$65.00-70.00
5 Pieces(MOQ)
Sample Available
Gc Packed Column for Sulfur Analysis 2m * 3mm, 60~80 Mesh, PTFE Tubing, Compatible with ASTM D5504 / ISO 20729

Gc Packed Column for Sulfur Analysis 2m * 3mm, 60~80 Mesh, PTFE Tubing, Compatible with ASTM D5504 / ISO 20729

US$198.00-228.00
1 Set(MOQ)
Sample Available
5% Phenyl Methylpolysiloxane General Purpose Gc Column for EPA Methods HP-5ms Alternative

5% Phenyl Methylpolysiloxane General Purpose Gc Column for EPA Methods HP-5ms Alternative

US$170.00
1 Set(MOQ)
Sample Available
Gas Chromatograph Column Micro Packed Gc Column for Sale

Gas Chromatograph Column Micro Packed Gc Column for Sale

US$62.00
1 Piece(MOQ)
Sample Available
100% Dimethicone Gc-1 Wall Coated Open Tubular Column

100% Dimethicone Gc-1 Wall Coated Open Tubular Column

US$120.00
1 Set(MOQ)
Sample Available

Sourcing guidance for Gc Capillary Column

What are the key technical specifications to consider when selecting a GC capillary column?

Buyers must focus on the stationary phase (polarity), internal diameter (I.D.), film thickness, and column length. For high-resolution needs, a 0.25mm I.D. is standard, while 0.53mm (megabore) columns are better for high-capacity injections. Ensure the stationary phase is chemically bonded and cross-linked to minimize column bleed and extend the lifespan under high temperatures.

How do I ensure the column is compatible with my specific gas chromatography system?

Verify the maximum operating temperature of the column against your oven's capabilities. Additionally, check the ferrule and nut sizes required for the inlet and detector interfaces. Most professional suppliers on Made-in-China.com provide columns compatible with major brands like Agilent, Shimadzu, and Thermo Fisher, but you should confirm the fused silica tubing quality to ensure flexibility and break-resistance during installation.

What compliance and quality certifications should I request from a supplier?

For laboratory-grade equipment, prioritize suppliers with ISO 9001 certification. Each column should come with an individual Performance Evaluation Chromatogram (Test Report) that details the theoretical plate count, retention indices, and peak asymmetry factors. This document serves as proof that the specific column meets the advertised efficiency standards before shipping.

Which stationary phase is best for different application scenarios?

For non-polar compounds like hydrocarbons, a 100% Dimethylpolysiloxane (e.g., CP-Sil 5 CB) is ideal. For environmental analysis or pesticides, 5% Phenyl-95% Dimethylpolysiloxane is the industry standard. If you are analyzing polar solvents or alcohols, a Polyethylene Glycol (Wax) phase is required. Always match the column polarity to the analytes to ensure proper separation.

Cross-Border Procurement & Risk Management for GC Columns

What are the primary risks when shipping GC capillary columns internationally?

The main risk is physical breakage due to the fragile nature of fused silica. Ensure the supplier uses shock-absorbent packaging and a rigid outer box. Another risk is thermal degradation if the column is exposed to extreme heat during transit; request vacuum-sealed moisture-proof bags and avoid long-duration sea freight for high-precision analytical components.

How can I negotiate better terms and ensure transaction security?

Utilize Trade Assurance services on Made-in-China.com to protect your payment until delivery is confirmed. When negotiating, ask for tiered pricing based on annual volume rather than a single order. For first-time buyers, request a sample column at a discounted rate to run a standard test mix in your lab before committing to a bulk purchase of 10+ units.

What should I look for in a supplier's after-sales and technical support?

Professional sourcing requires a supplier who offers technical application support, including help with method development or troubleshooting ghost peaks. Confirm the warranty period (typically 90 days for manufacturing defects) and ensure they have a clear replacement policy if the column fails the initial installation test (checkout) upon arrival.

What are the customs and shipping considerations for laboratory consumables?

Ensure the HS Code (typically 3822.00 or 9027.90) is correctly declared to avoid delays. Since these are high-value, low-weight items, Air Express (DHL/FedEx/UPS) is the recommended shipping method to minimize handling and ensure door-to-door tracking. Verify if your country requires specific import permits for laboratory chemicals if the column is pre-conditioned with specific reagents.

Related queries