Ph probe
I have found results from20000+products and6000+suppliers aboutPh probe
High Precision Semi-Micro pH Electrode Probe with BNC-S8 Connector for Accurate Measurements
E-201-Z Customized PCB pH Probe with RS485 Output for Foods
MADSUR PH Probe/Sensor MDS-900P Water Quality Tester 0-14PH with High Resolution, Accuracy
Industrial pH Probe for Semiconductor and Petrochemical Applications, Double Junction Design
Durable pH Probe for Industrial Use with Refillable Electrolyte Feature
High-Precision Digital pH Probe with RS485 Output for Online Monitoring
Top Selling Online Industrial pH Electrode pH Probe for Wastewater
High Accuracy pH Sensor Probe for Water Quality Monitoring
Wide pH Range Residual Chlorine Probe with Control Transmitter for Variable Water Conditions
Rika Rk500-09 Sewage Treatment ORP Cod Do pH Ec/Salinity Nh4+Turbidity Probe
Advanced 4-20mA RS485 Soil pH Probe for Greenhouse Agriculture
Source Manufacture Waterproof Connector Process pH Probe for Agriculture
Inline pH Probe for Reliable Measurement in Cooling Loops
Boqu pH 5806 High Temperature Industrial pH Sensor Glass Probe with 4-20mA Output
Boqu pH-8022 Environmental Protection Sensor pH Meter/pH Probe
RS485 Modbus pH Probe for Stadium Water Supply Control
RS485 Modbus pH Probe for Kitchen Water Treatment Systems
Digital RS485 pH Probe for Accurate Water Quality Detection
High Temperature Resistance OEM Custom pH Probe for Chemical Processes
Reliability Abrasion Resistance Customizable pH Sensor Probe for Domestic Sewage
Reliability Customizable Water pH Sensor Probe for Wastewater Treatment
Sourcing guidance for Ph Probe
What are the key technical specifications to consider when selecting a pH probe for industrial or laboratory use?
When sourcing pH probes, you must prioritize the junction type (e.g., ceramic, PTFE, or open) based on the sample's viscosity and the glass membrane shape (spherical for general use, flat for surfaces). Ensure the probe features Automatic Temperature Compensation (ATC) to maintain accuracy across varying thermal conditions. For industrial integration, verify the output signal compatibility, such as 4-20mA, RS485 Modbus, or BNC connectors, to ensure seamless connection with existing PLC or monitoring systems.
How do I ensure the pH probe meets international quality and compliance standards?
Professional buyers should verify that the supplier holds ISO 9001 certification for quality management. The products themselves should ideally carry CE marking for safety and RoHS compliance to ensure they are free from hazardous substances. For specialized applications, such as food or pharmaceutical industries, look for FDA-compliant materials or 3-A Sanitary Standards to prevent contamination.
What factors influence the lifespan and economic feasibility of pH probes in high-volume procurement?
The lifespan of a pH probe typically ranges from 6 to 24 months depending on the environment. To optimize Total Cost of Ownership (TCO), consider purchasing refillable electrodes which, although higher in initial cost, offer longer service life than sealed units. Evaluate the cost-to-performance ratio by requesting data on drift rates and response times; a probe that requires less frequent calibration reduces labor costs significantly over time.
What are the usage scenarios and maintenance requirements for different types of pH probes?
Usage scenarios range from wastewater treatment and hydroponics to chemical processing. For harsh environments (high pressure or oily samples), select double-junction probes to prevent electrolyte poisoning. Maintenance is critical: ensure the supplier provides storage solutions (typically 3M KCl) and buffer powders (pH 4.01, 7.00, 10.01). Probes should never be stored in distilled water, as this leaches the ions from the glass membrane, leading to permanent damage.
Cross-Border Procurement Considerations for pH Probes
What are the common risks when purchasing pH probes from overseas suppliers?
The primary risk is dehydration of the reference electrode during long-transit shipping. Ensure the supplier uses secure, leak-proof caps filled with storage solution and robust packaging to prevent glass breakage. Another risk is incompatibility with local voltage or connectors; always double-check if the probe requires a specific pre-amplifier or if the thread size (e.g., PG13.5) matches your installation housing.
How can I negotiate effectively with pH probe manufacturers on Made-in-China.com?
Focus on Tiered Pricing based on annual volume rather than a single order. Request a sample for lab validation before committing to a bulk purchase. You can also negotiate for customized cable lengths or private labeling (OEM) at lower MOQs if you are a distributor. Ask for a guaranteed shelf life (typically 12 months) for unused probes to protect your inventory investment.
What transaction security tips should be followed for international trade?
Utilize Trade Terms like FOB or CIF to clearly define the point of risk transfer. For payment security, use secured payment services provided by reputable platforms like Made-in-China.com to ensure funds are only released upon proof of shipment. Always request a Third-Party Inspection Report (e.g., SGS or Intertek) for large orders to verify the accuracy and slope of the probes before they leave the factory.
What are the logistics and customs precautions for shipping pH probes to international markets?
pH probes contain liquid electrolytes (potassium chloride), which may be classified as 'sensitive goods' by some couriers. Ensure the supplier provides a Material Safety Data Sheet (MSDS) to facilitate smooth customs clearance. For shipping to regions like the US or EU, ensure the HS Code (typically 9027.90) is correctly declared to avoid tariff disputes and ensure compliance with local import regulations.




























