SourcingAI

Oxygen pressure regulator

I have found results from20000+products and8000+suppliers aboutOxygen pressure regulator

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Oxygen
Type: Breathing Apparatus
with Verifying Pointer
General Pressure Gauge
Type: Self-Operated
Media: Gas
Certification: CE
Temperature: Ordinary Temperature
Connection: Thread
Valve Seat: Single-Seat
Structure: Diaphragm
Material: Stainless Steel
Measuring Range: Medium-pressure Gauge
Accuracy: 1
Display: Pointer
Application: Industrial
Connection Type: Axial
Local Indication Type
Installation Structure: Direct Mounting
General Pressure Gauge
General Pressure Gauge
Style: Desktop
Customized: Customized
Scale: Medium
Main Application: Nature Gas
Measuring Media: Gas
Measuring Principle: Electrical Principles
Standard: Standard
Connection Mode: Internal Thread
Power: Manual
Connection Form: Thread
Driving Mode: Manual
Nominal Pressure: PN1.0-32.0MPa
Straight Through Type
Certification: ISO
Certification: ISO13485
Certification: FDA
Certification: EEC
Certification: GS
Certification: RoHS
Certification: ISO9001
Certification: CCC
Temperature: High Temperature
Temperature: Low Temperature
Valve Seat: Double-Seat
Fluid Column Pressure Gauge
Structure: Piston
Structure: Lever
Spring Pressure Gauge
Material: Wall Type
Material: Brass
Material: Alloy
Measuring Range: High-pressure Gauge
Accuracy: 4
Accuracy: 1.6
Accuracy: 2.5
Application: Civil
Application: Industrial Usage
Water Industrial Usage
Connection Type: Radial Direction
Function: Electric Signal-controlled
Features of Measurement Medium: Corrosion Resistant
Differential Pressure Gauge
Customized: Non-Customized
Scale: Small

Sourcing guidance for Oxygen Pressure Regulator

What are the critical technical specifications to consider when sourcing an Oxygen Pressure Regulator?

Buyers must prioritize material compatibility and pressure ratings. The body should ideally be made of forged brass with chrome plating or anodized aluminum to ensure high-pressure resistance and prevent oxidation. Key specs include an inlet pressure range of up to 150-200 bar and an adjustable outlet flow rate (typically 0-15L/min for medical use). Ensure the regulator features a sintered bronze inlet filter to prevent particulate contamination and a safety relief valve that automatically vents if pressure exceeds a set threshold.

Which international compliance standards are mandatory for this product category?

For medical-grade regulators, compliance with ISO 10524-1 (Pressure regulators for use with medical gases) is essential. Depending on the target market, you must verify CE Marking (Medical Device Directive) for Europe, FDA Registration for the U.S., or UL/CSA certification for industrial applications. Additionally, ensure the connection threads match regional standards, such as CGA 540 or CGA 870 for North America and Bullnose (BS 341 No. 3) for the UK and parts of Asia.

How can I verify the safety and performance of the regulator before bulk shipment?

Request a hydrostatic pressure test report and a leakage test certificate from the supplier. It is critical to confirm that the product has undergone ultrasonic cleaning to be 'Oxygen Clean,' meaning it is free from oils and greases which can cause spontaneous combustion in high-pressure oxygen environments. For high-volume orders, hiring a third-party inspector to perform a random flow-rate accuracy test is highly recommended.

What are the common usage scenarios and how do they affect product choice?

Selection depends on the environment: Medical regulators require integrated flowmeters and humidification bottle connectors for patient therapy. Industrial regulators (used in welding or cutting) require dual gauges to monitor both cylinder pressure and working pressure. For emergency EMS use, a compact, lightweight click-style regulator with a DISS or barb outlet is preferred for portability and ease of use under stress.

Cross-Border Procurement Risks and Strategic Advice

What are the primary risks when importing Oxygen Pressure Regulators across borders?

The biggest risk is regulatory non-compliance, leading to customs seizures or legal liability if the device fails in a medical setting. Another risk is material substitution, where a supplier might use lower-grade alloys to save costs. To mitigate this, use Made-in-China.com's 'Audited Supplier' reports to verify the factory's specialized production licenses and quality management systems.

How should I negotiate pricing and MOQs with professional suppliers?

Focus on Total Cost of Ownership (TCO) rather than just the unit price. Professional manufacturers usually offer tiered pricing; for example, a 15% discount for orders over 500 units. Negotiate for spare parts inclusion (like extra O-rings or washers) and ask for customized branding/labeling to be included in the price for orders exceeding a specific MOQ (usually 200-500 units).

What are the best practices for shipping and transaction security?

Oxygen regulators are sensitive instruments; ensure the contract specifies anti-vibration packaging and moisture-proof sealing. For transaction security, utilize Secured Payment services on Made-in-China.com to ensure funds are only released after you confirm the goods meet the agreed-upon specifications. For shipping to the US or Europe, ensure the HS Code (typically 9022.20 or 8481.10) is correctly declared to avoid tariff penalties.

How can I ensure long-term supply chain stability for this technical product?

Establish a Quality Agreement that defines the acceptable failure rate (AQL). Prioritize suppliers who offer at least a 1-2 year warranty and have a dedicated technical support team. It is advisable to maintain a diversified supplier base on Made-in-China.com to avoid disruptions caused by regional logistics issues or raw material price fluctuations.

Related queries