SourcingAI

Magnetic level indicator

I have found results from20000+products and10000+suppliers aboutMagnetic level indicator

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Dial Indicator
High Frequency Ultrasonic Sensor
Type: Floating Ball
Type: Float
Vortex Flow Meter
Principle: Magnetic Sensors
Range: >0-30m
Measurement Accuracy: ±8mm
Accuracy: 1%
Kind: Magnetic Flap
All in One
Warranty: 1 Year
Certification: CE
Material: SS304
Process Temperature: -40~250℃
Application: Industrial
Display: Digital
Local Indication Type
Installation Structure: Direct Mounting
Features of Measurement Medium: Corrosion Resistant
Measurement Object: Length
Resolution: 0.002mm
Measure Method: Manual
Precision Measuring Device
Customized: Customized
Output Signal Type: Digital Type
Production Process: Injection
Sensitivity: High
Probe Type: Angle Probe
Measuring Medium: Gas
Direct Reflection Type
IP Rating: IP65
Contact: Contact
Feature: Corrosion Resistant
Main Application: Water
Sensor: Tube/Flange
Measuring Media: Liquid
Principle: FBG
Principle: Piezoelectric Type
Range: 0-10m
Range: 0-15m
Range: 0-30m
Range: 0-5m
Measurement Accuracy: ±3mm
Measurement Accuracy: ±5mm
Accuracy: 0.5
Accuracy: 0.1%
Accuracy: 0.25%
Accuracy: 0.2%
Liquid Level Transmitter
Spring Pressure Gauge
Certification: DIN
Certification: GB
Certification: RoHS
Certification: ISO
Material: SS360L
Material: Stainless Steel
Process Temperature: -20℃~80℃
Process Temperature: -190~425℃
Process Temperature: -80~300℃
Process Temperature: -40~300℃
Application: Environmental Protection
Measurement Object: Closed Pipeline
Output Signal Type: Analog Type
Production Process: Integration
Production Process: Normal Wirewound
IP Rating: IP68
Main Application: Wastewater
Main Application: Diesel Fuel
Main Application: Fuel Oil
Main Application: Nature Gas
Main Application: Corrosive Liquid/Gas

Sourcing guidance for Magnetic Level Indicator

What are the key technical specifications to consider when selecting a Magnetic Level Indicator (MLI)?

When sourcing an MLI, you must prioritize material compatibility and pressure-temperature ratings. Ensure the chamber is made of 304 or 316L Stainless Steel for standard corrosion resistance, or Hastelloy/PTFE lining for aggressive chemicals. The float design is critical; it must be engineered to match the specific gravity (SG) of your medium—typically requiring a minimum SG of 0.45 to 0.5. Additionally, verify that the center-to-center distance matches your tank nozzles and that the visual flags are made of high-temperature resistant ceramic or aluminum rather than plastic to prevent melting in steam applications.

Which international compliance standards are mandatory for Magnetic Level Indicators in industrial environments?

For global trade, the product must adhere to ASME B31.3 (Process Piping) or PED 2014/68/EU (Pressure Equipment Directive) for structural integrity. If the device is used in hazardous areas, ATEX or IECEx certification is non-negotiable to ensure the magnetic switches and transmitters are intrinsically safe or explosion-proof. For boiler applications, look for ASME Section I compliance. Always request Material Test Reports (MTRs) to verify the traceability of the metals used.

How can I ensure the accuracy and reliability of the magnetic coupling system?

Reliability depends on the magnetic flux strength of the float and the indicator flags. High-quality suppliers use Alnico or Neodymium magnets that maintain magnetism at high temperatures (up to 450°C). You should ask for a coupling test report to ensure the flags flip smoothly without 'dead zones.' For high-vibration environments, specify interlocking flags or damped indicators to prevent false readings caused by mechanical shock.

What integration options are available for remote monitoring?

Modern MLIs are rarely just visual. You should source units equipped with Reed Switch Transmitters or Magnetostrictive Transmitters that provide a 4-20mA signal with HART, Foundation Fieldbus, or Profibus protocols. This allows for seamless integration into a DCS or PLC system. Ensure the transmitter has an IP67 or IP68 ingress protection rating for outdoor or wash-down environments.

Cross-Border Procurement & Risk Management for Magnetic Level Indicators

What are the primary risks when shipping large-scale Magnetic Level Indicators internationally?

The main risk is mechanical damage to the glass or internal float during transit. MLIs are often long and slender, making them prone to bending. You must mandate wooden crate packaging with internal shock-absorbing foam and 'Do Not Bend' labeling. For units exceeding 3 meters, consider split-chamber designs to reduce shipping costs and the risk of structural failure during handling.

How should I negotiate quality assurance with suppliers on Made-in-China.com?

Focus on Third-Party Inspection (TPI). Stipulate in your contract that final payment is contingent upon a successful Hydrostatic Pressure Test (usually at 1.5x the design pressure) and a Helium Leak Test witnessed by an agency like SGS or TUV. Request a video FAT (Factory Acceptance Test) if you cannot be there in person to verify the float buoyancy in a medium of similar density to your actual process fluid.

What transaction security measures should be taken for high-value industrial equipment?

Use Secured Payment services provided by Made-in-China.com to ensure funds are only released after the Bill of Lading is verified. For custom-engineered MLIs, a common payment structure is 30% deposit / 70% against shipping documents. Avoid direct wire transfers to private accounts; always ensure the beneficiary name matches the company name on the business license and the Made-in-China.com audited profile.

How do I handle customs and import duties for specialized measuring instruments?

Ensure the supplier uses the correct HS Code (typically 9026.10) for instruments measuring the level of liquids. Incorrect classification can lead to hefty fines or seizure. Verify if your country has anti-dumping duties on stainless steel products from the sourcing region. Always request a Certificate of Origin (Form E or Form F) to take advantage of any applicable Free Trade Agreements (FTAs) which can reduce import tariffs to 0-5%.

Related queries