Hplc vial
I have found results from10000+products and3000+suppliers aboutHplc vial
2ml glassware Laboratory Hplc Vials for Autosampler Instrument
Clear Transparent 2ml Autosampler Vials with Caps Chromptochrpy HPLC Vials Clear Sample Vial with Screw Caps
2ml Clear HPLC Vials with Write Spot 9mm Wide Opening Chromatography Vial
300UL Lab 9-425 Screw Autosampler Micro-Vial Integrated Inserts with Label for HPLC
Lab Chromatography Borosilicate Glass 12X32mm 2ml 9-425 Cheap HPLC Autosampler Sample Vials
1.8ml HPLC Vials 2ml Amber Vial Borosilicate Glass 3.3 with Crimp Caps for Lab Sample Prepare
Write-on Marking Amber 1.5ml 9mm Vial Screw HPLC Vial 9-45
8-425 Vial Screw Amber HPLC Vial 2ml Small Opening V835/V837
Sample Customization Lab 2ml 9mm Wide Opening Screw Glassware HPLC Autosampler Vial
1.5ml 11mm Snap Ring PP Vial HPLC Vial Micro-Insert VP101
Clear Transparent 2ml Autosampler Vials with Caps Chromptochrpy HPLC Vials Clear Sample Vial with Screw Caps
Manufacturing 10ml 20ml HPLC Vials Chromatography Autosampler Vials Laboratory Detection Headspace Vials
Alwsci 2ml 1.5ml Amber Chromatography Gc Crimp Micro Vial for HPLC
Alwsci HPLC Gc 2ml 11mm PP Snap Vial with 0.7ml Micro-Vial
Alwsci HPLC 2ml Screw Top Amber Glass Barcode Vial 2D Code
Alwsci Agilent HPLC Autosampler Vial ND9 1.5ml 2ml Clear Glass Vial with Writing Area
Alwsci HPLC Clear Glass 2ml Vial with Integrated 0.2ml Glass Micro-Insert.
Alwsci 9-425 HPLC PP Vial Micro Insert IC Testing Laboratory Glassware
Sourcing guidance for Hplc Vial
What are the key material specifications to consider when selecting HPLC vials?
The most critical factor is the glass type. You should prioritize USP Type I Borosilicate glass (33-expansion or 51-expansion) to ensure low metal content and high chemical resistance. For light-sensitive samples, Amber glass is essential to prevent photodegradation. If working with proteins or low-concentration analytes, consider Low Adsorption (Deactivated) vials to minimize sample loss due to surface binding.
How do I choose the correct septa and cap combination for my application?
The choice depends on your solvent and needle type. PTFE/Silicone septa are the industry standard for general use, offering excellent resealability. For aggressive solvents like alkanes or ethers, PTFE/Red Rubber is a cost-effective alternative for single injections. Ensure the cap is compatible with your autosampler (e.g., 9-425 screw thread is standard for Agilent, while 11mm crimp or snap caps are common for other brands).
What compliance standards should a professional B2B buyer verify?
Suppliers should provide evidence of ISO 9001 certification for quality management. For pharmaceutical and high-precision labs, look for Certificate of Analysis (CoA) for each batch, confirming dimensions and cleanliness. Ensure the products meet USP and EP (European Pharmacopoeia) standards for hydrolytic resistance to avoid leaching issues during analysis.
How can I evaluate the technical compatibility of vials with my laboratory equipment?
Verify the vial dimensions (typically 12x32mm) and the neck finish. Use robotic-compatible screw caps if using high-throughput automated systems to prevent mechanical jams. For small volume samples, check if the supplier offers integrated micro-inserts which provide better alignment and higher recovery than loose inserts.
Cross-Border Procurement & Risk Management for HPLC Vials
What are the primary risks when importing glass consumables internationally?
The biggest risks are breakage during transit and chemical contamination. You must mandate double-wall corrugated export packaging with internal dividers. To prevent contamination, ensure vials are shrink-wrapped in clean-room environments before being boxed. Request a small trial shipment to test the supplier's packaging integrity before committing to a full container.
How should I negotiate with suppliers on Made-in-China.com for bulk orders?
Focus on Tiered Pricing and Quality Consistency. Ask for a price break at the 10,000, 50,000, and 100,000 unit levels. Instead of just pushing for the lowest price, negotiate for free replacement of damaged goods and a guaranteed lead time (typically 15-25 days). Requesting pre-shipment samples from the actual production batch is a standard professional safeguard.
What are the best practices for shipping and customs clearance for lab consumables?
Ensure the HS Code (typically 7017.90) is correctly declared to avoid customs delays. For shipping to the US or EU, verify if the supplier is familiar with ISF filing or VAT/EORI requirements. For high-value or urgent batches, Air Freight is recommended to reduce handling, but for bulk stock, Sea Freight (LCL/FCL) is more economical if the packaging is robust.
How can I ensure transaction security and supplier reliability?
Utilize the Secured Trading services provided by Made-in-China.com to protect your payment until delivery. Prioritize Audited Suppliers who have undergone third-party onsite inspections by SGS or Bureau Veritas. Always verify the supplier's export history to your specific country to ensure they understand your local regulatory landscape.





























