SourcingAI

Electric air damper

I have found results from50000+products and10000+suppliers aboutElectric air damper

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Industrial Fan Heater
Type: Gas-Filled
Material: Plastic
Shape: Universal
Hinge Material: Plastic
Slow-Close Toilet Seats
With Slow Down
Color: Multi Color
Pattern: With Pattern
User: Adult
Usage: Home
Warranty: 3 Year
ventilation mode: mechanical ventilation
Air Tube Material: Galvanized Sheet
Noise Level: Low
Mounting: Wall/Window Mount
Lifetime: >20 years
Certification: CE
Condition: New
Part: Dampers
Position: Front
Spring Type: Air Spring
Spring Material: Steel
Structure: Double Cylinder
Suitable for Car Brands: Nissan
Damping Force Direction: Bidirectional
Media: Gas
Driving Mode: Electric
Connection Form: Flange
Seal Form: Auto Sealed
Valve Stem: Normal
Mid-Pressure (2.5mpa< Pn <6.4mpa)
Low Temperature (-100°C
Metal Hard Sealed
Valve Body: Sheet Metal
Application: Industrial Usage
Adjustable: Yes
Driving Style: On-Road
Corrosion Durability: Ultrahigh
Operating Voltage: 380/400 VAC
Application Fields: Medicine
Power Source: Electric Power
Connection: Flange
Venetian-Style Air Layers: Single
Installation: Duct Fans
Material: Stainless Steel
Children's Toilet Seats
Feature: Electronic Bidets
LED Toilet Seats
for Air Conditioner
Usage: for Refrigerate
Noise Level: Ultra Low
Mounting: Floor Standing
Lifetime: 15~20 years
Certification: ISO
Certification: CCC
Certification: ISO9001
Certification: EAC
Certification: TUV
Certification: GOST
Certification: ROHS
Position: Rear
Spring Type: Coil Spring
Structure: Double-Eccentric Sealing
Structure: Centre Sealing
Low Pressure (Pn<1.6mpa)
Medium Temperature (120°C
Material of Seal Surface: Soft Sealed
Water Industrial Usage

Sourcing guidance for Electric Air Damper

How to choose the right Electric Air Damper for industrial or HVAC applications?

Selecting the correct electric air damper requires a focus on actuator torque, material compatibility, and sealing performance. For industrial environments, prioritize stainless steel (304/316) or galvanized steel to prevent corrosion. Ensure the actuator torque (measured in Nm) is sufficient to overcome the static pressure of your duct system. For high-precision airflow control, look for modulating actuators (0-10V or 4-20mA) rather than simple on/off types. Additionally, verify the leakage class (e.g., EN1751 Class 4) to ensure energy efficiency and airtightness when the damper is closed.

What are the key technical specifications and compliance standards for Electric Air Dampers?

Buyers must ensure products meet CE, UL, or RoHS certifications for electrical safety and environmental compliance. Key technical benchmarks include the IP rating (typically IP54 or IP66) for dust and water resistance, especially for outdoor or humid installations. For fire safety systems, dampers must comply with UL555 or EN1366-2 fire resistance standards. Always request cycle test reports; high-quality dampers should withstand at least 50,000 to 100,000 cycles without mechanical failure.

How can I optimize cost-efficiency when procuring Electric Air Dampers in bulk?

To maximize value, calculate the Total Cost of Ownership (TCO), including energy consumption and maintenance. Purchasing pre-assembled actuator-damper units can reduce on-site labor costs by up to 20%. For large-scale projects, sourcing from manufacturers on Made-in-China.com allows for volume-based discounts (often 10-15% for orders over 100 units). Additionally, choosing standardized duct sizes (e.g., 100mm to 400mm) is significantly more cost-effective than requesting custom dimensions.

Cross-Border Purchasing Considerations for Electric Air Dampers

What are the common risks when importing Electric Air Dampers and how to mitigate them?

The primary risks include voltage incompatibility and shipping damage. Always confirm the local voltage (e.g., 24V AC/DC, 110V, or 220V) and frequency (50/60Hz) with the supplier before production. To prevent mechanical misalignment during transit, insist on reinforced plywood crate packaging rather than standard cardboard. Utilize third-party inspections (such as SGS or Intertek) to verify the actuator response time and limit switch functionality before the final balance payment is made.

What strategies should be used for negotiating with suppliers on Made-in-China.com?

Focus negotiations on warranty terms and technical support. Request a 2-year warranty instead of the standard 1-year, as actuators are the most common point of failure. Ask for spare parts (e.g., 2% extra gaskets or mounting brackets) to be included in the bulk price. For long-term partnerships, negotiate staggered payment terms (e.g., 30% deposit, 70% after inspection) to ensure the supplier maintains high quality throughout the production cycle.

How should shipping and international trade policies be handled for these products?

Electric air dampers contain electrical components, so ensure the supplier provides the correct HS Code (typically 8481.80 or 8414.90) to avoid customs delays and incorrect tariff applications. For urgent projects, Air Freight is viable for actuators, but for heavy steel dampers, Sea Freight (FOB or CIF) is the most economical. Ensure all documentation includes a Certificate of Origin to take advantage of potential Free Trade Agreements (FTA) between China and your specific country.

Related queries