SourcingAI

Automatic led emergency light

I have found results from40000+products and20000+suppliers aboutAutomatic led emergency light

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Sensor
Color Temperature: Cool White
Emitting Color: Cool White
IP Rating: IP66
Power: >100W
Application: Industrial
Voltage: 220V
Voltage Type: AC
Certification: CCC
Usage: Anti-theft
Installation Mode: Wall Mounted
Bulb Type: LED
Light Range: 50-100m
Lighting Period (H): 3
Material: Plastic
Power Supply: Dry Battery
Battery Type: Lead-acid
With Remote Control
Shade Direction: Down
Input Voltage: 220v
Shade Type: Toughened Glass
Emergency Time: 3-4h
Operation Mode: Maintained
Warranty: 2 Years
Projection Distance: >35m
Body Material: Stainless Steel
Lighting Bulbs & Tube: Energy Saving
Average Life: >8000h
Operating Voltage: 220-240V
Light Source: LED Light
Lamp Body Material: Aluminum Alloy
Lamp Power: 200W
Installation: Stand
Lamp Holder/Base: E27
Color Temperature: Warm White
IP Rating: IP33
IP Rating: IP65
IP Rating: IP67
Power: 11-15W
Power: 3W
Application: Industry
Application: Special Equipment
Application: Traffic
Application: Highway
Application: Square
Application: Garden
Certification: CE
Certification: CQC
Certification: EMC
Certification: RoHS
Certification: FCC
Certification: ISO
Certification: GS
Certification: SAA
Certification: VDE
Certification: LVD
Usage: Fire Lights
Usage: Spot Lighting
Lighting Period (H): 5
Material: Aluminum
Cold Rolled Steel Sheet
Power Supply: Solar
Battery Type: Ni-Cd
Input Voltage: 100-240V
Emergency Time: 6-7h
Warranty: 3 Years

Sourcing guidance for Automatic Led Emergency Light

What are the key technical specifications to consider when sourcing Automatic LED Emergency Lights?

Buyers should prioritize Battery Type and Capacity, specifically looking for Lithium Iron Phosphate (LiFePO4) or Ni-Cd batteries that offer at least 90 to 180 minutes of discharge duration. Ensure the LED luminous efficacy is high (typically >100 lm/W) to provide sufficient brightness during power outages while maintaining energy efficiency. Additionally, verify the IP Rating (e.g., IP65 for outdoor or industrial use) and the Switchover Time, which should be less than 0.5 seconds to ensure seamless safety transitions.

Which international compliance standards are mandatory for these products?

Compliance is critical for fire safety equipment. For the US market, products must meet UL 924 (Emergency Lighting and Power Equipment) standards. For European markets, CE (LVD/EMC) and EN 60598-2-22 certifications are required. Global buyers should also look for RoHS compliance to ensure the absence of hazardous substances and ISO 9001 certification for the manufacturer to guarantee consistent production quality.

How can I evaluate the durability and reliability of the emergency light's internal components?

Request test reports for Overcharge and Over-discharge Protection circuits, as these prevent battery swelling and fire risks. The housing should be made of Flame-Retardant ABS or PC materials with a UL94 V-0 rating. Ask the supplier for MTBF (Mean Time Between Failures) data and confirm if the product includes a Self-Diagnostic Function, which automatically tests the battery and lamp status monthly, reducing manual maintenance costs.

Cross-Border Procurement & Risk Management for Emergency Lighting

What are the specific risks associated with shipping LED emergency lights internationally?

The primary risk involves Lithium Battery Regulations. Emergency lights contain batteries, which are classified as Class 9 Dangerous Goods. You must ensure the supplier provides a valid UN38.3 Test Report and an MSDS (Material Safety Data Sheet). Failure to provide these will lead to customs seizures or rejection by airlines/shipping lines. For sea freight, ensure the batteries are packed according to IMDG standards to prevent short circuits during transit.

How should I negotiate with suppliers on Made-in-China.com to ensure transaction security?

Always utilize the Secured Trading Service on Made-in-China.com to protect your payments until the goods are received and inspected. When negotiating, request a Pre-shipment Inspection (PSI) by a third party like SGS or Intertek. Define a clear Defective Rate Clause in your contract; for electronic safety products, the acceptable AQL (Acceptable Quality Level) should be 1.0 for major defects and 2.5 for minor defects.

What strategies can be used to mitigate the impact of international trade policies and tariffs?

Stay informed about Anti-dumping duties or specific Section 301 tariffs (for US buyers) that may apply to LED products. To optimize costs, consider FOB (Free On Board) terms to maintain control over your logistics chain and insurance. Additionally, verify if your country has a Free Trade Agreement (FTA) with the supplier's country to obtain a Certificate of Origin (Form E or Form P), which can significantly reduce or exempt import duties.

Related queries