SourcingAI

Photo bio reactor alga

I have found results from200+products and100+suppliers aboutPhoto bio reactor alga

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Tubular Reactor
Type: Fermentation Extraction
Type: Reaction Kettle
Type: Tank Reactor
Structure: Multiple Parallel
Pressure: Positive
Agitator Model: Paddle Agitator
Heating: Electric Heating
Automatic Grade: Automatic
Condition: New
Material: Glass
Application: Granules
Application Area: Chemical
Certification: CE
Cooling Method: Water Cooling
Main Material: Stainless Steel
Mixing Drum Shape: Conical
Stirring Type: Spiral
Reaction Pressure Vessel
Storage Medium: Moncombustible/Nontoxic
Capacity: 50-100L
Heat Transfer Structure: Jacketed
Plate Tower Reactor
Customized: Customized
Heating Method: Electric Heating
Structure: Single Tube
Pressure: Atmospheric
Pressure: Negative
Agitator Model: Ribbon Agitator
Agitator Model: Turbine Agitator
Hot Water Heating
Automatic Grade: Semi-Automatic
Material: Stainless Steel
Material: Glass-Lined
Application: Liquid
Liquid with Suspended Solids
Application: Powder
Application: Viscous Fluid
Application Area: Food
Application Area: Pharmaceutical
Certification: ISO
Certification: GMP
Certification: CE Certified
Certification: GMP Compliant
Certification: ISO Certified
Spray Tower Reactor
Packed Tower Reactor

Sourcing guidance for Photo Bio Reactor Alga

What are the key technical specifications to consider when selecting a Photo Bio Reactor?

When sourcing a PBR, prioritize the light path length, as it directly impacts photosynthesis efficiency; a path of 50mm to 100mm is standard for high-density cultures. Ensure the material is high-borosilicate glass or UV-stabilized PMMA to guarantee maximum light transmittance and longevity. Additionally, verify the aeration and mixing system (e.g., airlift or bubble column) to ensure uniform nutrient distribution and prevent cell sedimentation without causing shear stress to the algae.

How do I evaluate the automation and control systems of a PBR?

A professional-grade PBR must include an integrated PLC control system capable of real-time monitoring of pH, temperature, dissolved oxygen (DO), and CO2 concentration. Look for systems that offer automated nutrient dosing and data logging capabilities. For large-scale operations, ensure the software supports remote monitoring and is compatible with standard industrial protocols like Modbus or Ethernet/IP.

What compliance and sterilization standards are required for algae production?

For food or pharmaceutical grade algae (like Spirulina or Chlorella), the equipment must meet GMP (Good Manufacturing Practice) standards. Ensure all wetted parts are made of SS316L stainless steel or food-grade plastics. The system should support CIP (Clean-in-Place) or SIP (Sterilize-in-Place) processes to prevent contamination, which is the leading cause of batch failure in commercial algae farming.

What are the typical usage scenarios for different PBR designs?

Tubular PBRs are ideal for outdoor large-scale commercial production due to their high surface-to-volume ratio. Flat-plate PBRs are best for laboratory research and high-value nutraceuticals where light utilization must be maximized. For startup phases or wastewater treatment, column PBRs offer a cost-effective footprint with simplified maintenance.

Cross-Border Procurement & Risk Management for PBR Systems

How can I mitigate the risk of damage during international shipping?

PBRs often contain fragile glass or acrylic components. You must mandate vacuum-sealed wooden crate packaging with shock-absorption foam. It is highly recommended to use Made-in-China.com's secured payment services and insist on CIF (Cost, Insurance, and Freight) terms so the supplier handles the insurance for transit damage. Always request a pre-shipment pressure test video to ensure no leaks exist before the unit leaves the factory.

What strategies should be used when negotiating with PBR suppliers?

Focus negotiations on the warranty period for sensors and probes, as these are high-wear items; aim for at least 24 months. Discuss spare parts kits (seals, gaskets, and valves) to be included in the initial PO. For bulk orders, leverage the scalability of the control system to reduce the per-unit cost of software licensing.

How do I ensure the PBR complies with my country's import regulations?

Verify that the electrical components (motors, sensors, PLCs) carry CE, UL, or CSA certification depending on whether you are importing to Europe or North America. Failure to provide these can lead to customs seizures or the inability to pass local fire and safety inspections. Request the HS Code (typically 841989) from the supplier early to calculate accurate import duties and VAT.

What after-sales support should I expect for complex bio-machinery?

Demand a technical support agreement that includes video installation guidance and a guaranteed 24-hour response time for troubleshooting. Since these systems involve biological processes, ask if the supplier provides initial culture parameters or 'recipes' for specific algae strains to shorten your commissioning phase.

Related queries